RHTemp1000 Data Logger
Rugged, Stand-Alone, Humidity and Temperature Data Logger with a Stainless Steel enclosure
TEMPERATURE
Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -20 °C to +80 °C (-4 °F to +176 °F)
Temperature Resolution 0.01 °C
Temperature Calibrated Accuracy ±0.5 °C

HUMIDITY
Humidity Range 0 %RH to 100 %RH (non-condensing)
Humidity Resolution 0.1 %RH
Humidity Calibrated Accuracy ±3 %RH maximum; ±2 %RH typical at 25 °C

GENERAL
Memory 16,350 readings per channel
Reading Rate 1 reading every second to 1 reading every 24 hours
Battery Life 2 years typical at 25 °C, 15 minute reading intervals
Material 316 Stainless Steel
Dimensions 1.0 in x 2.0 in dia. (25.4 mm x 50.8 mm)
Operating Environment -20 °C to +80 °C, 0 %RH to 95 %RH
Required Interface Package IFC400, IFC406
Approvals CE

RHTemp1000IS Data Logger
Intrinsically Safe, Rugged, Water Resistant, Stand Alone, Humidity and Temperature Data Logger
TEMPERATURE
Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -20 °C to +80 °C (-4 °F to +176 °F)
Temperature Resolution 0.01 °C
Temperature Calibrated Accuracy ±0.5 °C (0 °C to 55 °C)

HUMIDITY
Humidity Sensor Capacitive Digital Humidity Sensor
Humidity Range 0 %RH to 100 %RH (non-condensing)
Humidity Resolution 0.1 %RH
Humidity Calibrated Accuracy ±3 %RH maximum; ±2.0 %RH typical at 25 °C

GENERAL
Memory 16,350 readings per channel
Reading Rate 1 reading every second to 1 reading every 24 hours
Battery Life 2 years typical at 25 °C, 15 minute reading intervals
Material 316 Stainless Steel
Dimensions 1.0 in x 2.0 in dia. (25.4 mm x 50.8 mm)
Operating Environment -20 °C to +80 °C, 0 %RH to 95 %RH non-condensing
Required Interface Package IFC400
Approvals CE, IS Rated

RHTemp1000IS R1
The RHTemp1000IS is available in Aluminum or Stainless Steel
TEMPERATURE
Temperature Sensor Internal semiconductor
Temperature Range -40 °C to +80 °C
Temperature Resolution 0.1 °C
Temperature Calibrated Accuracy ±0.5 °C

HUMIDITY
Humidity Sensor Internal semiconductor
Humidity Range 0 %RH to 100 %RH
Humidity Resolution 0.5 %RH
Humidity Calibrated Accuracy ±3 %RH
RH Units %RH, dew pt., water vapor, concentration (mg/hl)

GENERAL
Memory 21,845/channel
Reading Rate 1 reading every 2 seconds up to 1 reading every 12 hours
Baud Rate 2,400
Battery Life 1 year
Material Available in aluminum or stainless steel
Dimensions 5.4 in x 1.0 in dia. (138 mm x 26 mm)
Operating Environment -40 °C to +80 °C, 0 %RH to 100 %RH
Required Interface Package IFC110 or IFC200
Approvals CE

EggTemp-RH Data Logger
Egg Shaped Temperature and Humidity Data Logger.
TEMPERATURE
Temperature Sensor Internal semiconductor
Temperature Range 0 to +60 °C
Temperature Resolution 0.1 °C
Temperature Calibrated Accuracy ±0.5 °C

HUMIDITY
Humidity Sensor Internal semiconductor
Humidity Range 0 %RH to 95 %RH
Humidity Resolution 0.5 %RH
Humidity Calibrated Accuracy ±3.0 %RH
RH Units %RH, dew pt., water vapor, concentration (mg/hl)

GENERAL
Memory 16,383/channel
Reading Rate 1 reading every 2 seconds up to 1 reading every 12 hours
Baud Rate 38,400
LED Indicators Red & Green
Battery Life 1 year
Material Enclosure: HDPE
Logger: Stainless Steel
Dimensions 2.25 in x 1.68 in dia. (57.15 mm x 42.67 mm)
Operating Environment 0 °C to +60 °C, 0 %RH to 95 %RH non-condensing
Required Interface Package IFC102

RHTemp101A Data Logger
State-of-the-art Humidity and Temperature Data Logger
TEMPERATURE
Temperature Sensor Precision RTD Element
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution 0.01 °C (0.018 °F)
Temperature Calibrated Accuracy ±0.5 °C (±0.9 °F)

HUMIDITY
Humidity Sensor Internal semiconductor
Humidity Range 0 %RH to 95 %RH
Humidity Resolution 0.1 %RH
Humidity Calibrated Accuracy ±3.0 %RH (±2 %RH typical at 25 °C/77 °F)
RH Units %RH, dew pt., water vapor, concentration (mg/hl)

GENERAL
Memory 1,000,000 readings per channel; software configurable memory wrap
500,000 readings in multiple start/stop mode
Reading Rate 1 reading every second up to 1 reading every 24 hours
Alarm Yes, Humidity
Baud Rate 115,200
LED Indicators Red & Green
Push-Button Start Yes
Battery Life 10 years typical at a 15 minute reading rate
Material ABS plastic
Dimensions 1.4 in x 2.2 in x 0.6 in (36 mm x 56 mm x 16 mm)
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 95 %RH non-condensing
Required Interface Package IFC200
Approvals CE

TempRetrieverRH Data Logger
Low Cost, Reusable, Humidity and Temperature Data Logger with LED Indicators.
TEMPERATURE
Temperature Sensor Semiconductor
Temperature Range -40 °C to +80 °C
Temperature Resolution 0.1 °C
Temperature Calibrated Accuracy ±0.5 °C (0 to +50 °C)

HUMIDITY
Humidity Sensor Semiconductor
Humidity Range 0 %RH to 95 %RH
Humidity Resolution 0.1 %RH
Humidity Calibrated Accuracy 3 %RH (2 %RH typical at 25 °C)

GENERAL
Memory 16,383 readings per channel
Reading Rate 1 reading every 5 seconds up to 1 reading every 30 minutes
Baud Rate 38,400
LED Indicators Red & Green
Push-Button Start Yes
Battery Life 1 year
Material ABS plastic
Dimensions 1.4 in x 2.2 in x 0.6 in (36 mm x 56 mm x 16 mm)
Operating Environment -40 °C to +80 °C, 0 %RH to 95 %RH non-condensing
Required Interface Package IFC110 or IFC200
Approvals Approved for carriage on Delta® Mainline Flights

RHTemp2000 Data Logger
Humidity and Temperature Data Logger with LCD (Wall mounted power adapter included)
TEMPERATURE
Temperature Sensor Internal semiconductor
Temperature Range -20 °C to +60 °C
Temperature Resolution 0.1 °C
Temperature Calibrated Accuracy ±0.5 °C

HUMIDITY
Humidity Sensor Internal semiconductor
Humidity Range 0 %RH to 95 %RH
Humidity Resolution 0.1 %RH
Humidity Calibrated Accuracy ±3.0 %RH
RH Units °C, °F, K, °R; %RH, mg/ml water vapor concentration, dew point

GENERAL
Memory 131,071/channel
Reading Rate 1 reading every 2 seconds to 1 every 24 hours
Baud Rate 115,200
Battery Life 1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage. Optional AC Adapter available.
Material Black anodized aluminum
Dimensions 4.8 in x 3.3 in x 1.25 in (122 mm x 84 mm x 32 mm)
Operating Environment -20 °C to +60 °C, 0 %RH to 95 %RH non-condensing
Required Interface Package IFC200
Approvals CE

Madgetech